Pile Driver KH240V Maruzenkogyo 商品番号:MAR-020E
Most popular pile driver with
φ80 mm post cover
Optional cap adapters allow you to drive many different sizes of pile and pipe.
・APPLICATIONS
1. For driving guard rail pipe.
2. For driving steel pipe for fencing at worksite.
3. For driving foundation of solar power generation.
4. For driving earth retainer pile.
Please let us know if you want to ask more...
・your information(name, address, telephone number)
・quantity
・delivery address
- 販売単位:
- 価格:
- お問合せください
MODEL | KH240V |
dimensions(mm) | 629×265×154 |
weight(kg) | 24.5 |
working pressure(MPa) | 7.8~11.8 |
maximum pressure(MPa) | 20.6 |
flow range(ℓ/min) | 20 |
allowable back pressure(MPa) | 2.5 |
coupling | 3/8inch couplers |
capacity(mm) | φ80 (φ100, φ120mm Option) |
hydraulic oil | ISO VG32(Standard), ISO VG46 orequivalant |
max hose length(m) | 3/8"×10 |
blow per minute(bpm) | 1080 |
HOW TO USE
1. Connect the pile driver with hydraulic power source.
2. Start the power unit or other power source, let it runs for a while to warm up the engine.
3. Use ∅4mm wire to lift the pile driver (Refer to the drawing on the right)
4. Place pile vertically on the point which you intended to drive in.
Set the pile driver on the top of pile. Be cautious not to let the pile driver falls.
5. Grip the control grip and handle pipe.
Press the pile driver downward.
Start the pile driver by clasping the control grip downward.
6. Make sure that pile stays vertically without inclination.
7. While pile has been driven in to the desired depth, Stop the pile driver.
8. Remove the pile driver from the pile.
9. Stop the power source and detach the connection hoses.
MAINTENANCE
Ask your dealer for the periodical inspections.