お気軽にお問い合せください
05224250010522425003 受付時間 8:30~17:30(土日祝日を除きます) E-mail:info@hodumi.co.jp

Power Unit UH070 Maruzenkogyo 商品番号:MAR-029E

POWER UNIT UH070

・Wide range of tools can be used with only a compact power pack.

・Light weight, compact, and portable.
Only 40kg! Can be carried on a mini-van easily.

・Can be stored three-tier stacking.

Please conntact us with information below if you want to ask more...
・your information(name, address, telephone number)
・quantity
・delivery address

販売単位:
価格:
お問合せください

MODEL UH070  
dimension(mm) 615×480×610
weight(kg)  40
max pressure(Mpa) 11.7
engine Honda GX200
oil flow(ℓ/min) 20.5
spark plug BR6HS(NGK) RL86C(Champion)
fuel tank capacity 3.2(Max 2hours with fuel fhrottle)
hydraulic reservoie capacity(L) 4
engine startingRecoil Starter
batteryUH130-2ES : 12V/18Amp
coupling3/8" couplers
hydraulic oilISO VG32 or equivalent
othersequipped with an air cooling oil cooler / folding handle

APPLICABLE HYDRAULIC ATTACHMENTS
Hydraulic Handheld Breaker BH051 / BH112 / BH230 / BH16VS / BH18K・18RK / BH20EV・20EVR /
BH23K・23RK / BH051V / BH112V / BH161V
Hydraulic Pile Driver KH192 / KH240V / KH800
Hydraulic Rick Drill DH204 / DH205
Hydraulic Concrete Cutter DH130
Hydraulic Handheld Auger CH01 / AY01H
Hydraulic Water Pump PH300
Hydraulic Core Cutter DH-190H-2

HOW TO USE

1. Before Starting Engine:
(1) Engine Oil:
Check the engine oil level by oil gauge.
Refill engine oil when the oil is below the min. level.
Recommended engine oil: SAE 10W-30 or equivalent. Capacity: 0.6L

(2) Hydraulic Oil:
Refill hydraulic oil when the oil level is below the oil indication window.
Open the plug on the top of the oil tank,
pour in hydraulic oil till the oil level reach to the middle of the indication window.
Recommended hydraulic oil: ISO VG32 or equivalent. Capacity: 4L

(3) Fuel:
Refill gasoline into the fuel tank.
Capacity: 3.6L
* Wipe out spilled gasoline on machines.

2. Starting Engine:
(1) Attach power unit and equipment (breakers and etc.) with connection hoses before starting engine.
DO NOT start engine without connecting to equipment with hoses.
MAKE SURE control lever indicate to “START” position.

(2) Start operation



①Open the fuel cock.

②Turn the switch to “ON”

③Turn the speed control lever from low speed (L) toward to high speed (H) and stop at 1/3 closer to (H) position.

④Close the choke lever.
When to open the choke lever:
・When the weather is cold or when the engine is cold, close the choke lever.
・When the weather is warm or when starting the engine right after stopping,
fully or partially open the choke.

⑤Pull start rope gradually.
DO NOT pull the starting rope rapidly.
After the rope being fully pulled, DO NOT release it from your hand.
Hold the starting rope till it returns to its original position.

⑥After the engine being started, open the choke lever.
Open the choke lever gradually according to the engine’s condition.
Eventually, the choke lever should be fully opened.
・When the weather is cold, engine might stop if you turn the choke lever too rapidly.

3. Operation:
(1) Turn the throttle to high speed (H)

(2) Turn the control lever to the “OPERATE” position.
(Refer to the drawing on the right)

(3) Read through all operating manuals of equipment which you intend to use with this power unit.

(4) When stopping the operation of the equipment (breakers and etc.) ALWAYS turn the engine throttle to the Low Speed (L) side.
This can save energy and reduce the noise level.

4. Stop:
(1) Turn the speed control lever to Low Speed (L) side and run the machine for 1 to 2 minutes.

(2) Turn the switch to “O” Off side.

(3) Turn off the fuel cock.

(4) Detach connection hoses from equipment (breakers and etc.)
Connect couplers on the hoses together.

< CAUTION >
The temperature of the machine goes high while being operated.
Always wear gloves when operating the equipment (breakers and etc.)

管理番号:2826
受付時間:8:30~17:30
(土日祝及びGW・夏季休暇・年末年始は休み)
お問い合せ